CAD Cart (0)
  • Cart is empty
  • Low-Pressure-Check-Valves_Low


    Provide unidirectional flow and tight shut-off for liquids and gases with high reliability. When differential drops below cracking pressure*, valve shuts off. (Not for use as relief valve.)

    Materials: 316 Stainless Steel: body, cover, poppet and cover gland. 300 Series Stainless Steel: spring Standard O-ring: Viton, for operation to 500° F (260°C). Buna-N or Teflon available for 250°F (121°C) or 400°F (204°C) respectively; specify when ordering.

    Cracking Pressure: 20 psi (1.38 bar) ±30%. Springs for higher cracking pressures (up to 100 psi (6.89bar)) available on special order for O-ring style check valves only.

    Minimum operating temperature for standard o-ring check valves 0°F (17.8°C).
    For low temperature option to -423°F (-252°C) add suffix LTTO (Low temperature spring & Teflon o-ring).

    Caution: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf life may vary widely with differing service conditions, properties of reactants, pressure and temperature cycling and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and O-rings replaced as required.

    Caution: See Tubing section for proper selection of tubing.
    Note: For optional material see Technical Information.

    Note: Special material check valves may be supplied with four flats in place of standard hex.

    All dimensions for reference only and subject to change.
    For prompt service, Autoclave stocks select products. Consult your local representative.
    All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.

  • Low-Pressure-Check-Valves_Low


    Prevent reverse flow where leak-tight shut-off is not mandatory. When differential drops below cracking pressure, valve closes. With all-metal components, valve can be used up to 1200°F (649°C). See Technical Information section for connection temperature limitations. (Not for use as a relief valve.)

    Ball and poppet are an integral design to assure positive, in-line seating without “chatter”. Poppet is designed essentially for axial flow with minimum pressure drop.

    Materials: 316 Stainless Steel: body, cover, cover gland, ball, poppet, cover gland. 300 Series Stainless Steel: ball,spring

    Minimum operating temperature for standard ball check valves -110° (-79°C).
    For low temperature option to -423°F (-252°C) add suffix LT (Low temperature spring).

    Caution: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf life may vary widely with differing service conditions, properties of reactants, pressure and temperature cycling and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and O-rings replaced as required.

    Caution: See Tubing section for proper selection of tubing.
    Note: For optional material see Technical Information.

    Note: Special material check valves may be supplied with four flats in place of standard hex.

    All dimensions for reference only and subject to change.
    For prompt service, Autoclave stocks select products. Consult your local representative.
    All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.

  • Low-Pressure-Check-Valves_Low


    Protects pressure gauges and pressure instrumentation from surges in flow or sudden venting in the event of line failure.

    Materials: 316 Stainless Steel: body, cover, sleeve, cover gland. 300 Series Stainless Steel: ball

    Vertical Installation: Since this type of check valve employs a non-spring loaded ball, valve MUST be installed in VERTICAL position with arrow on valve body pointing UP. (cover gland up).

    Resetting Valve: Equalize the pressure across the ball. The ball will drop and reset automatically.

    Caution: While testing has shown O-Rings to provide satisfactory service life, both cyclic and shelf life may vary widely with differing service conditions, properties of reactants, pressure and temperature cycling and age of the O-ring. FREQUENT INSPECTIONS SHOULD BE MADE to detect any deterioration, and O-rings replaced as required.

    Caution: See Tubing section for proper selection of tubing.
    Note: For optional material see Technical Information.

    Note: Special material check valves may be supplied with four flats in place of standard hex.

    All dimensions for reference only and subject to change.
    For prompt service, Autoclave stocks select products. Consult your local representative.
    All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.