Print Back

Low Pressure Valve Features:
  • 10V Series valve design provides in-line tube connections for 1/4" to 1/2" tube sizes.
  • Tubing sizes from 1/8" to 1/2".
  • Rising stem/barstock body design.
  • Non-rotating stem prevents stem
Unit of Measure

Specifications

Pressure Rating at Room Temperature

N/A 15000 psi1034 bar

Outside Diameter Tube

N/A 1/8 in3.18 mm

Stem Type

N/A REG

Valve Pattern

N/A 2-Way Straight

Connection Type

N/A W125

Orifice Diameter

N/A 0.094 in2.39 mm

A - Width

N/A 1.5 in38.10 mm

B - Length

N/A 0.75 in19.05 mm

C - Length

N/A 0.31 in7.87 mm

D - Height

N/A 1.06 in26.92 mm

D1 - Height

N/A 0.81 in20.57 mm

E - Height

N/A 1.38 in35.05 mm

F - Length

N/A 3.00 in76.20 mm

G - Packing Gland Mounting Hole Drill Size

N/A 0.62 in15.75 mm

G1 - Bracket Mounting Hole Size

N/A 0.17 in4.32 mm

H - Height

N/A 3.75 in95.25 mm

M - Length

N/A 0.56 in14.22 mm

N - Height

N/A 0.31 in7.87 mm

Block Thickness

N/A 0.62 in15.75 mm

Tubing Engagement Depth

N/A 0.47 in11.9 mm

Rated Cv

N/A 0.12

Valve Options

Valve Options

N/A Extreme Temperatures
Standard Autoclave valves with Teflon packing may be operated to 450°F (232°C). High temperature packing and/or extended stuffing box is available for service from 0°F (-17.8°C) to 650°F (343°C) by adding the following suffixes to catalog order number.†
TG standard valve with Teflon glass packing to 600°F (316°C).
GY standard valve with graphite braided yarn packing to 650°F (343°C).

† Autoclave Engineers does not recommend compression sleeve connections below 0°F (-17.8°C) or above 650°F (343°C). For additional valve options, contact your Sales Representative.

Valve Maintenance

Valve Maintenance

N/A Repair Kits:
add "R" to the front of valve catalog number for proper repair kit. (Example: R10V4071)

Valve Bodies:
Valve bodies are available. Order using the eight (8) digit part number found on the valve drawing or contact your Sales Representative for information.

Consult your Autoclave representative for pricing on repair kits and valve bodies. Refer to the Tools, Installation, Operation and Maintenance section for proper maintenance procedures.