Print Back
Autoclave Engineers high-pressure ball valves have been designed to provide superior quality for maximum performance within a variety of valve styles, sizes, and process connections. Some of the more unique design innovations include an integral one-piece trunion mounted style ball and stem that eliminates the shear failure common in two piece designs, re-torqueable seat glands that result in longer seat life, and a low friction stem seal that reduces actuation torque and enhances cycle life.

more
Unit of Measure

Specifications

Orifice

1 in

End Connection Number

P16

Connection Type

1 NPT

MAWP at Room Temperature

10000 psi690 bar

Minimum Orifice

1.00 in25.40 mm

Seat Gland Hex

1.88 in47.75 mm

A - Height

11.87 in301.50 mm

B - Length

8.41 in213.61 mm

C - Width

5.00 in127.00 mm

D - Length

14.00 in355.60 mm

E - Length

28 in711.20 mm

F - Height

3.10 in78.74 mm

G - Spacing of Holes

4.00 in101.60 mm

H - Dimension

2 in50.80 mm

J - Dimension

0.88 in22.35 mm

K - Diameter

0.53 in13.46 mm

L - Height

5.46 in138.68 mm

Block Thickness

3.38 in85.85 mm

A - Panel Mounting Dimension

4.00 in101.60 mm

B - Panel Mounting Dimension

2.00 in50.80 mm

C - Panel Mounting Dimension

2.94 in74.70 mm

D - Panel Mounting Dimension

0.44 in11.20 mm

E - Panel Mounting Dimension

1.50 in38.10 mm

Valve Options

N/A Valve Actuators
Consult Factory

Actuator Operating Temperature:
Pneumatic: -20°F to 75°F (-29°C to 79°C)
Electric: -20°F to 60°F (-29°C to 7 °C)

High Temperature Option:
HT - for media temperature up to 500°F (260°C)

Valve Maintenance

N/A Repair Kits:
add “R” to the front of valve catalog first 4 numbers for proper repair kit. (Example: R2B16S)

Consult your Autoclave representative for pricing on repair kits. Refer to the Operation and Maintenance manual for proper maintenance procedures.