CAD Cart (0)
  • Cart is empty

Low Pressure Valve Features:
  • 10V Series valve design provides in-line tube connections for 1/4" to 1/2" tube sizes.
  • Tubing sizes from 1/8" to 1/2".
  • Rising stem/barstock body design.
  • Non-rotating stem preven
Unit of Measure

Pressure Rating at Room Temperature

N/A 15000 psi1034 bar

Outside Diameter Tube

N/A 1/8 in3.18 mm

Stem Type

N/A VEE

Valve Pattern

N/A 2-Way Straight

Connection Type

N/A W125

Orifice Diameter

N/A 0.094 in2.39 mm

A - Width

N/A 1.5 in38.10 mm

B - Length

N/A 0.75 in19.05 mm

C - Length

N/A 0.31 in7.87 mm

D - Height

N/A 1.06 in26.92 mm

D1 - Height

N/A 0.81 in20.57 mm

E - Height

N/A 1.38 in35.05 mm

F - Length

N/A 3.00 in76.20 mm

G - Packing Gland Mounting Hole Drill Size

N/A 0.62 in15.75 mm

G1 - Bracket Mounting Hole Size

N/A 0.17 in4.32 mm

H - Height

N/A 3.75 in95.25 mm

M - Length

N/A 0.56 in14.22 mm

N - Height

N/A 0.31 in7.87 mm

Block Thickness

N/A 0.62 in15.75 mm

Tubing Engagement Depth

N/A 0.47 in11.9 mm

Rated Cv

N/A 0.12

Valve Options

N/A Extreme Temperatures
Standard Autoclave valves with Teflon packing may be operated to 450°F (232°C). High temperature packing and/or extended stuffing box is available for service from 0°F (-17.8°C) to 650°F (343°C) by adding the following suffixes to catalog order number.†
TG standard valve with Teflon glass packing to 600°F (316°C).
GY standard valve with graphite braided yarn packing to 650°F (343°C).

† Autoclave Engineers does not recommend compression sleeve connections below 0°F (-17.8°C) or above 650°F (343°C). For additional valve options, contact your Sales Representative.

Valve Maintenance

N/A Repair Kits:
add "R" to the front of valve catalog number for proper repair kit. (Example: R10V4071)

Valve Bodies:
Valve bodies are available. Order using the eight (8) digit part number found on the valve drawing or contact your Sales Representative for information.