High Pressure Valve Features:
  • Tubing sizes from 1/4” to 3/8”.
  • Non-rotating stem prevents stem/seat galling.
  • 100,000 PSI (6900 bar) max pressure
  • Metal-to-metal seating achieves bubble-tight shut- off, longer stem/seat life in abrasive flow, greater durability for repeated on/off cycles and excellent corrosion resistance.
  • Stem sleeve and packing gland materials have been selected to achieve extended thread cycle life and reduced handle torque.
  • Choice of Vee or Regulating stem tips.
  • Cold-worked type 316 stainless steel body with aluminum bronze packing gland and non-rotating stem.
  • Nylon and leather packing below stem threads.
Autoclave valves are complemented by a complete line of high pressure fittings and tubing. The high pressure series uses Autoclave’s coned-and-threaded connections for dependable performance in gas or liquid service.

The 100V Series valves are furnished complete with connection components, unless otherwise specified.

Panel mounting drill size: 0.22" all valves.
All dimensions for reference only and subject to change.
For prompt service 'Autoclave stocks select products' Consult factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Unit of Measure

Pressure Rating at Room Temperature

N/A 100000 psi6895 bar

Outside Diameter Tube

N/A 1/4 in6.35 mm

Stem Type

N/A VEE

Valve Pattern

N/A 2-Way Straight

Connection Type

N/A F312C150

Orifice Diameter

N/A 0.062 in1.57 mm

A - Width

N/A 3.00 in76.20 mm

B - Length

N/A 1.50 in38.10 mm

C - Length

N/A 0.52 in13.21 mm

D - Height

N/A 1.75 in44.45 mm

D1 - Height

N/A 1.44 in36.58 mm

E - Height

N/A 2.25 in57.15 mm

F - Length

N/A 4.00 in101.60 mm

G - Packing Gland Mounting Hole Drill Size

N/A 1.12 in28.45 mm

G1 - Bracket Mounting Hole Size

N/A 0.34 in8.64 mm

H - Height

N/A 5.32 in135.13 mm

M - Length

N/A 1.12 in28.45 mm

N - Height

N/A 0.50 in12.70 mm

Block Thickness

N/A 1.38 in35.05 mm

Tubing Engagement Depth

N/A 1.18 in30.0 mm

Rated Cv

N/A 0.09

N/A Extreme Temperatures
Standard AE valves with Teflon packing may be operated to 450°F(232°C), and to 230°F (110°C) with nylon-leather packing.
K - anti-vibration collet and gland assembly.

For other packing options consult the factory.

N/A Repair Kits:
add "R" to the front of valve catalog number for proper repair kit. (Example: R100VM15071)

Valve Bodies:
Valve bodies are available. Order using the eight (8) digit part number found on the valve drawing or contact your Sales Representative for information.