Print Back
Series RVP relief valves provide reliable venting of gases or liquids for set pressures from 3000 psi (206 bar) minimum to 75000 psi (5171 bar). The standard temperature range for all models is -423° to 400° (-252° to 204°C). A high temperature option to 750°F (399°C) is also available.

These precision valves are designed for pressure gas systems, cryogenic systems, petrochemical applications and other special systems. Capable of handling air, gases, steam, vapor and liquids, they are however, not recommended for steam boiler applications nor are they ASME code stampable.

All RVP models are designed primarily for thermal expansion or low volume relief applications at high pressures where flow is not critical. Thus, liquid curves for these models are not shown.

Options: Autoclave Engineers can supply various inlet and outlet connections on special order. A high temperature option is also available for temperatures to 750°F (399°C) for RVP models.
To specify high temperature option: Add suffix “HT” for 750°F (399°C) high temperature option.

Caution:
1. AE relief valves are preset and factory sealed. Warranty is voided if seal is broken by customer.
2. Maximum system operating pressure should not exceed 90% of relief valve set pressure. Operating pressures in excess of this may cause weepage resulting in damage to the plug and seat.

Ordering Instructions: To permit prompt and correct responses to your order, we will require the following information: quantity, valve catalog number, service requirements (liquid, gas & vapor), set pressure (PSIG - bar), and service temperature range.

Caution should be exercised in proper selection of medium pressure tubing based on actual operating conditions. Two series available: 15000 (1034 bar) and 20000 (1380 bar).

For prompt service, Autoclave stocks select products. Consult factory.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Relief_valves
Unit of Measure
1 

Item #

Inlet Connection

Outlet Connection NPT

Orifice Diameter

Pressure Rating psi (bar) @100°F (38°C) - Minimum Setting

Pressure Rating psi (bar) @100°F (38°C) - Maximum Setting

Pressure Rating psi (bar) @100°F (38°C) - Maximum Back Pressure

5RVP9072 N/A SF562CX N/A 3/4 in N/A 0.312 in7.92 mm N/A 3000 psi207 bar N/A 5000 psi345 bar N/A 500 psi34.47 bar
10RVP9072 N/A SF562CX N/A 3/4 in N/A 0.250 in6.35 mm N/A 5000 psi345 bar N/A 10000 psi690 bar N/A 500 psi34.47 bar
15RVP9072 N/A SF562CX N/A 3/4 in N/A 0.188 in4.78 mm N/A 10000 psi689.46 bar N/A 15000 psi1034.20 bar N/A 500 psi34.47 bar
20RVP9072 N/A SF562CX N/A 3/4 in N/A 0.156 in3.96 mm N/A 15000 psi1034.20 bar N/A 20000 psi1378.93 bar N/A 500 psi34.47 bar
30RVP6072 N/A F375C N/A 3/4 in N/A 0.125 in3.18 mm N/A 20000 psi1378.93 bar N/A 30000 psi2068.39 bar N/A 500 psi34.47 bar
45RVP9072 N/A F562C N/A 3/4 in N/A 0.093 in2.36 mm N/A 25000 psi1723.66 bar N/A 45000 psi3102.59 bar N/A 500 psi34.47 bar
60RVP6072 N/A F375C N/A 3/4 in N/A 0.078 in1.98 mm N/A 30000 psi2068.39 bar N/A 60000 psi4136.79 bar N/A 500 psi34.47 bar
75RVP5072 N/A F312C150 N/A 3/4 in N/A 0.062 in1.57 mm N/A 37000 psi2551.02 bar N/A 75000 psi5170.99 bar N/A 500 psi34.47 bar
Unit of Measure
1