Autoclave Engineers high-pressure ball valves have been designed to provide superior quality for maximum performance within a variety of valve styles, sizes, and process connections. Some of the more unique design innovations include an integral one-piece trunion mounted style ball and stem that eliminates the shear failure common in two piece designs, re-torqueable seat glands that result in longer seat life, and a low friction stem seal that reduces actuation torque and enhances cycle life.

These ball valves can also be modified to incorporate the use of special materials, seals for high temperature applications, subsea models, and valve actuators.

When it comes to high-pressure applications, these ball valves with the associated high-pressure components, provide the critical performance demanded by the high pressure market.

AE Ball Valve Features:
  • One-piece, trunion mounted style, stem design eliminates shear failure found in two piece designs and reduces effects of side loading.
  • Re-torqueable seat glands for longer seat life.
  • Carbon filled PEEK seats offer excellent resistance to chemicals, heat, and wear/abrasion.
  • Full-port flow path minimizes pressure drop.
  • 316 cold worked stainless steel construction.
  • Low friction pressure assisted graphite filled Teflon stem seal increases cycle life and reduces operating torque.
  • Available in 90° turn diverter and 80° turn switching models.
  • Viton o-rings for operation from 0°F (-17.8°C) to 400°F (204°C).
  • Optional o-rings available for high-temperature applications.
  • Optional wetted materials.
  • Wide selection of tube and pipe and fittings available.
  • Electric and pneumatic actuator options.
Applications:

  • Laboratories
  • Test Stands
  • Control Panels
  • Chemical Research
  • Pilot Plants
  • Water Blast Pumping Units
  • High volume chemical injection skids.
See ball valve option/detail section for end connection details, material, and high temperature options.
All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold.
Ball-Valves_4-Way-Series
Unit of Measure
Items Ball-Valves_4-Way-Series
4B6S10L8
4-Way Series Ball Valves
Ball-Valves_4-Way-Series
4BS6S10L8
4-Way Series Ball Valves
Ball-Valves_4-Way-Series
4B6S10M6
4-Way Series Ball Valves
Ball-Valves_4-Way-Series
4BS6S10M6
4-Way Series Ball Valves
Ball-Valves_4-Way-Series
4B6S10M9
4-Way Series Ball Valves
Orifice N/A 3/8 in
End Connection Number N/A L8 N/A L8 N/A M6 N/A M6 N/A M9
Connection Type N/A SW500 N/A SW500 N/A SF375CX20 N/A SF375CX20 N/A SF562CX20
MAWP at Room Temperature N/A 10000 psi690 bar
Minimum Orifice N/A 0.375 in9.52 mm N/A 0.375 in9.52 mm N/A 0.203 in5.16 mm N/A 0.203 in5.16 mm N/A 0.312 in7.92 mm
Seat Gland Hex N/A 1.38 in35.05 mm
A - Height N/A 5.81 in147.57 mm
B - Length N/A 6.79 in172.47 mm
C - Width N/A 3.50 in88.90 mm
D - Length N/A 5.13 in130.30 mm
E - Length N/A 10.25 in260.35 mm
F - Height N/A 1.63 in41.40 mm
G - Spacing of Holes N/A 2.63 in66.80 mm
H - Dimension N/A 1.31 in33.27 mm
J - Dimension N/A 0.41 in10.41 mm
K - Diameter N/A 0.28 in7.11 mm
L - Height N/A 2.97 in75.44 mm
Block Thickness N/A 3.50 in88.90 mm
A - Panel Mounting Dimension N/A 2.63 in66.68 mm
B - Panel Mounting Dimension N/A 1.31 in33.34 mm
C - Panel Mounting Dimension N/A 1.88 in47.63 mm
D - Panel Mounting Dimension N/A 0.28 in7.11 mm
Valve Options N/A Pneumatic Actuator
AO - Air-to-open/spring to close
AC - Air-to-close/spring to open
AOC - Air-to-open-and-close (double action)

Electric Actuator
EO1 - 120 volt AC 50/60 Hz
EO2 - 220 volt AC 50/60 Hz
EO3 - 24 VDC

Actuator Operating Temperature:
Pneumatic: -20°F to 175°F (-29°C to 79°C)
Electric: -20°F to 160°F (-29°C to 71°C)
Note: Consult factory for additional actuator information.

High Temperature Option:
HT - for media temperature up to 500°F (260°C)
Valve Maintenance N/A Repair Kits: add “R” to the front of valve catalog first 4 (5 for switching) numbers for proper repair kit. (Example: R4B6S)

Consult your Autoclave representative for pricing on repair kits. Refer to the Operation and Maintenance manual for proper maintenance procedures.